elx_mes0220: FDMI rsp failed
DESCRIPTION: An error response was received to FDMI request.
DATA:(1) SWAP_DATA16(fdmi_cmd)
SEVERITY: Information
LOG: LOG_DISCOVERY verbose
ACTION: The fabric does not support FDMI, check fabric configuration.
elx_mes0221: FAN timeout
DESCRIPTION: A link up event was received without the login bit set, so the driver
waits E_D_TOV for the Fabric to send a FAN. If no FAN if received, a FLOGI will
be sent after the timeout.
DATA: None
SEVERITY: Warning
LOG: LOG_DISCOVERY verbose
ACTION: None required. The driver recovers from this condition by issuing a
FLOGI to the fabric.