Platform Independent errors - 001 to 099
lpfcN: 1 : Stray ELS completion
Received an ELS command completion without issuing a corresponding ELS
command (based on the IOTAG field in the CMD_ELS_REQUEST_CR IOCB). The
IOCB command and IOTAG are used to match are recorded.
ACTION: This error could indicate a software driver or firmware problem. If the
problems persist, report these errors to technical support.
ERROR always fcelsb.c
lpfcN: 2 : ELS [command response] completion error
An ELS command completed with a status error in the IOCB. The IOCB command,
IOCB status, IOCB parameter error, as well as the PortID this ELS command was
directed to are recorded. This is only a warning. It could mean
❍ The Fibre Channel device on the network is not responding.
❍ The Fibre Channel device is not an FCP target.
The Fibre Channel driver will automatically retry this ELS command if needed.
ACTION: If the ELS command is a PLOGI or PRLI, and the destination PortID is
not an FCP target, no action is needed. Otherwise, check the physical connections
to the Fibre Channel network and the state of the remote PortID.
WARNING ELS verbose fcelsb.c
Emulex Documentation, Drivers, and Software
Comentarios a estos manuales