lpfcN: 42 : Xmit sequence completion error
A XMIT_SEQUENCE command completed with a status error in the IOCB. The
IOCB status, the IOCB IOTAG, the IOCB parameter error, as well as the PortID
this command was directed to are recorded. The driver attempts to recover by
creating a new exchange to the remote device.
ACTION: If there are many errors on one device, check the physical connections to
the Fibre Channel network and the state of the remote PortID.
WARNING IP verbose fcxmitb.c
lpfcN: 43 : Stray CreateXRI completion
Received a CREATE_XRI command completion without issuing a corresponding
CREATE_XRI command (based on the IOTAG field in the CREATE_XRI_CR
IOCB). The IOCB command and IOTAG used to match are recorded.
ACTION: This error could indicate a software driver or firmware problem. If the
problems persist, report these errors to technical support.
ERROR always fcxmitb.c
lpfcN: 44 : Adapter failed to initialize
The host adapter failed to initialize properly. The status register is recorded.
ACTION: This error usually indicates a hardware problem with the adapter, run
diagnostics.
ERROR always lp6000.c