Emulex LP9802DC Manual de usuario Pagina 60

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 69
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 59
lpfcN: 39 : Cannot issue FCP command
A valid login with a target no longer exists. The target NPortID, SCSI ID and LUN
are recorded.
ACTION: Check the state of the target in question.
WARNING always fcstratb.c
lpfcN: 40 : No room on IP xmit queue
The system is generating IOCB commands to be processed faster than the adapter
can process them.
ACTION: Check the state of the link. If the link is up and running, reconfigure the
xmit queue size to be larger. Note, a larger queue size may require more system IP
buffers. If the link is down, check physical connections to the Fibre Channel
network.
WARNING IP verbose fcxmitb.c
lpfcN: 41 : Stray XmitSequence completion
Received an XMIT_SEQUENCE IOCB completion without issuing a corresponding
XMIT_SEQUENCE command (based on the IOTAG field in the
XMIT_SEQUENCE_CR IOCB). The IOCB command and IOTAG used to match
are recorded.
ACTION: This error could indicate a software driver or firmware problem. If the
problems persist,report these errors to technical support.
ERROR always fcxmitb.c
Emulex Documentation, Drivers, and Software
60
Vista de pagina 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 68 69

Comentarios a estos manuales

Sin comentarios