Emulex LightPulse LPe1105-M4 HBA Guía de instalación Pagina 168

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 182
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 167
168
EMC Host Connectivity with Emulex FC HBAs and FCoE CNAs for the Linux Environment
Special Instructions
CLARiiON “Ghost” LUN reported with the Emulex v7.1.14 and
v7.3.2 drivers (PQB filter)
EMC supports the Emulex v7.1.14 driver that is integrated into the
RHEL 3.0 U4 (v2.4.21-27.EL) and U5 (v2.4.21-32.EL) kernels and the
Emulex v7.3.2 driver that is integrated into RHEL: 3.0 U6. When
using these quarterly updates and the integrated Emulex driver,
parameter value modifications must be made via an edit to
/etc/modules.conf, rather than lpfc.conf.
When running these RHEL 3.0 quarterly updates in CLARiiON
environments, it is highly recommended that the lpfc_inq_pqb_filter
parameter be enabled. In certain environments, there have been cases
where the SCSI mid-layer exits a SCSI disk scan incorrectly or
prematurely due to a mishandling of the response from the
INQUIRY
command.
The following are symptoms of this issue:
1. When an initiator is zoned to multiple targets on the same
CLARiiON storage system, the scan of the SCSI bus will succeed
and the list of devices on the first initiator-target pair will be
enumerated. However, the SCSI bus scan is not issued on any
targets, other than the first. The premature exit of the SCSI bus
scan results in the reporting of a “ghost” LUN for each instance of
a failed initiator-target pair, as well as an incomplete enumeration
of the available disks using the failed initiator-target pairs, and
the unavailability of target-side failover.
2. If a SCSI host initiator is zoned to only one target on a CLARiiON
storage system, the initiator incorrectly enumerates a "ghost"
LUN in addition to the actual devices in the host Storage Group.
The CLARiiON “ghost” LUN is reported in the
/proc/scsi/scsi file
as a DGC Direct-Access device, but no Model type is displayed.
An example of this incorrect reporting is shown below:
more /proc/scsi/scsi
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: RAID 5 Rev: 0207
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi2 Channel: 00 Id: 00 Lun: 01
Vendor: DGC Model: RAID 5 Rev: 0207
Type: Direct-Access ANSI SCSI revision: 04