Emulex LP10000ExDC Manual de usuario Pagina 250

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 366
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 249
elx_mes0317: Rsp ring <ringno> get: iotag <iotag> greater then configured
max <fast_iotag> wd0 <irsp>
DESCRIPTION: The assigned I/O iotag is greater than the maximum allowed.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver, firmware or hardware
problem. Report these errors to Technical Support.
elx_mes0318: Outstanding I/O count for ring <ringno> is at max <fast_iotag>
DESCRIPTION: An I/O tag cannot be assigned because none are available. The
maximum number of allowed I/Os are currently outstanding.
DATA: None
SEVERITY: Information
LOG:LOG_SLI verbose
ACTION: This message indicates the adapter HBA I/O queue is full. Typically this
happens when heavy I/O is running on a low-end (3 digit) adapter. We suggest you
upgrade to a higher-end adapter.
Emulex Documentation, Drivers and Software
250
Vista de pagina 249
1 2 ... 245 246 247 248 249 250 251 252 253 254 255 ... 365 366

Comentarios a estos manuales

Sin comentarios