elx_mes0321: Unknown IOCB command
DESCRIPTION: Received an unknown IOCB command completion.
DATA: (1) ulpCommand (2) ulpStatus (3) ulpIoTag (4) ulpContext)
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver or firmware problem. If these
problems persist, report these errors to Technical Support.
elx_mes0322: Ring <ringno> handler: unexpected completion IoTag <IoTag>
DESCRIPTION:The driver could not find a matching command for the completion
received on the specified ring.
DATA: (1) ulpStatus (2) ulpWord[4] (3) ulpCommand (4) ulpContext
SEVERITY: Warning
LOG: LOG_SLI verbose
ACTION:This error could indicate a software driver or firmware problem. If
problems persist report these errors to Technical Support.