elx_mes0405: Service Level Interface (SLI) 2 selected
DESCRIPTION: A CONFIG_PORT (SLI2) mailbox command was issued.
DATA: None
SEVERITY: Information
LOG: LOG_INIT verbose
ACTION: No action needed, informational.
elx_mes0406: Memory buffer pool is below low water mark
DESCRIPTION: A driver memory buffer pool is low on buffers.
DATA: (1) seg (2) fc_lowmem (3) low
SEVERITY: Warning
LOG: LOG_INIT verbose
ACTION: None required. The driver will recover as buffers are returned to the pool.