elx_mes1306: Link Down timeout
DESCRIPTION: The link was down for greater than the configuration parameter
(lpfc_linkdown_tmo) in seconds. All I/O associated with the devices on this link will
fail.
DATA: (1) hba_state (2) fc_flag (3) fc_ns_retry
SEVERITY: Warning
LOG: LOG_LINK_EVENT | LOG_DISCOVERY verbose
ACTION: Check the HBA cable/connection to the Fibre Channel network.
elx_mes1307: READ_LA mbox error <mbxStatus> state <hba_state>
DESCRIPTION: The driver cannot determine what type of link event occurred.
DATA: None
SEVERITY: Information
LOG: LOG_LINK_EVENT verbose
ACTION: If numerous link events are occurring, check the physical connections to
the Fibre Channel network. May indicate a possible hardware or firmware problem.