Emulex LP10000ExDC Manual de usuario Pagina 259

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 366
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 258
elx_mes0409: Memory Buffer Pool is out of buffers
DESCRIPTION: A driver memory buffer pool is exhausted.
DATA: (1) seg (2) fc_free (3) fc_mbox.q_cnt (4) fc_memhi
SEVERITY: Error
LOG: Always
ACTION: Configure more resources for that buffer pool. If the problem persists,
report the error to Technical Support.
elx_mes0410: Cannot find virtual addr for mapped buf on ring <num>
DESCRIPTION: The driver cannot find the specified buffer in its mapping table.
Thus it cannot find the virtual address needed to access the data.
DATA: (1) first (2) q_first (3) q_last (4) q_cnt
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver or firmware problem. If
problems persist report these errors to Technical Support.
Emulex Documentation, Drivers and Software
259
Vista de pagina 258
1 2 ... 254 255 256 257 258 259 260 261 262 263 264 ... 365 366

Comentarios a estos manuales

Sin comentarios