26 Sun Blade X6270 Server Module Product Notes December 2009
6766163
6766172
6771124
Legacy PCIe Hot-Plug Is Not Supported by SLES10 SP2
Issue:
SLES10 SP2 is not able to do legacy hot-plug on the Sun Blade X6270 Server
Module. During boot up the kernel loads the PCIE_AER driver. This driver gains
native (pciehp) control of PCIe hot-plug slots using the BIOS/ACPI _OSC
method. After this occurs, the legacy (acpiphp) hot-plug driver should never be
loaded.
Affected Operating Systems and Software:
SUSE Linux Enterprise Server 10 Service Pack 2 (SLES10 SP2)
Supplemental Software Releases 1.0, 1.1, 1.2, 1.4, 2.0, 2.0.1, 2.1
Workaround:
You must use the pciehp hot-plug driver with SLES10 SP2 on the Sun Blade
X6270 Server Module.
The acpiphp hot-plug driver should not be used with SLES10 SP2 on the Sun
Blade X6270 Server Module.
6771120 Benign Error Messages Are Seen When Using RHEL 5.3
Issue:
When using RHEL 5.3, benign error messages might be seen in the boot logs.
These benign messages are related to the PCI device probe of the Aspeed video
device.
Example of benign error messages:
PCI: Ignore bogus resource 6 [0:0] of 0000:20:05.0
Or
PCI: Ignore bogus resource 6 [0:0] of 0000:35:05.0
Affected Operating Systems and Software:
Red Hat Enterprise Linux (RHEL) 5.3
Supplemental Software Releases 1.0, 1.1, 1.2, 1.4, 2.0, 2.0.1, 2.1
Workaround:
These error messages are benign and have no effect on the system stability or
performance.