Driver for Linux -Troubleshooting Section Page 118
elx_mes0305: Mbox cmd cmpl error - RETRYing
DESCRIPTION: A mailbox command completed with an error status that causes the driver to reissue the
mailbox command.
DATA: (1) mbxCommand (2) mbxStatus (3) word1 (4) hba_state
SEVERITY: Information
LOG: LOG_MBOX verbose
ACTION: No action needed, informational.
elx_mes0306: CONFIG_LINK mbxStatus error <mbxStatus> HBA state <hba_state>
DESCRIPTION: The driver issued a CONFIG_LINK mbox command to the HBA that failed.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a firmware or hardware problem. Report these errors to Technical
Support.
elx_mes0307: Mailbox Cmpl, wd0 <pmbox> wd1 <varWord> wd2 <varWord> cmpl
<mbox_cmpl)
DESCRIPTION: A mailbox command completed.
DATA: None
SEVERITY: Information
LOG: LOG_MBOX verbose
ACTION: No action needed, informational.
elx_mes0308: Mbox cmd issue - BUSY
DESCRIPTION: The driver attempted to issue a mailbox command while the mailbox was busy processing
the previous command. The processing of the new command will be deferred until the mailbox becomes
available.
DATA: (1) mbxCommand (2) hba_state (3) sli_flag (4) flag
SEVERITY: Information
LOG: LOG_MBOX verbose
ACTION: No action needed, informational.
elx_mes0309: Mailbox cmd <cmd> issue
DESCRIPTION: The driver is in the process of issuing a mailbox command.
DATA: (1) hba_state (2) sli_flag (3) flag
SEVERITY: Information
LOG: LOG_MBOX verbose
ACTION: No action needed, informational.
elx_mes0310: Mailbox command <cmd> timeout
DESCRIPTION: A mailbox command was posted to the adapter and did not complete within 30 seconds.
DATA: (1) hba_state (2) sli_flag (3) mbox_active
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a software driver or firmware problem. If no I/O is going through the
adapter, reboot the system. If the problem persists, report the error to Technical Support.
Comentarios a estos manuales