Vista de pagina 156
Driver for Linux -Troubleshooting Section Page 151
elx_mes1203: N/A
DESCRIPTION: N/A
DATA: N/A
SEVERITY: N/A
LOG: N/A
ACTION: N/A
elx_mes1204: lpfc_kmalloc: bad virtual addr
DESCRIPTION: The driver manages its own memory for internal use. This error indicates that a problem
occurred in the driver memory management routines. This error could also indicate that the host system is
low on memory resources.
DATA: (1) i (2) size ( 3) type (4) fc_idx_dmapool
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a driver or host operating system problem. If the problem persists,
report the error to Technical Support.
elx_mes1205: lpfc_kmalloc: dmapool FULL
DESCRIPTION: The driver manages its own memory for internal use. This error indicates that a problem
occurred in the driver memory management routines. This error could also indicate that the host system is
low on memory resources.
DATA: (1) i (2) size ( 3) type (4) fc_idx_dmapool
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a driver or host operating system problem. If the problem persists,
report the error to Technical Support.
elx_mes1206: linux_kfree: Bad phba
DESCRIPTION: The driver manages its own memory for internal usage. This error indicates a problem
occurred in the driver memory management routines. This error could also indicate the host system in low
on memory resources.
DATA: (1) size (2) fc_idx_dmapool
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a driver or host operating system problem. If the problem persists,
report the error to Technical Support.
elx_mes1207: linux_kfree: NOT in dmapool
DESCRIPTION: The driver manages its own memory for internal use. This error indicates that a problem
occurred in the driver memory management routines. This error could also indicate that the host system is
low on memory resources.
DATA: (1) virt (2) size (3) fc_idx_dmapool
SEVERITY: Error
LOG: Always
ACTION: This error could indicate a driver or host operating system problem. If the problem persists,
report the error to Technical Support.