In the following example, the number of ports is "two" since "4" and "5" (two underlined portions) are
displayed as the SCSI Host numbers of the Converged Network Adapter card.
# ls /proc/scsi/lpfc820
4 5
4 Change the setting values of the parameter for the Converged Network Adapter card driver.
Driver parameter Setting value
lpfcX_lun_queue_depth Arbitrary (*1)
(Up to 512 for each FCoE port of the ETERNUS DX)
*1: Recommended value = 512 ¸ (number of FCoE ports that are connected to a single CA port) ¸
number of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower.
Use the following command to change the setting values when the driver parameter name is
"lpfcX_lun_queue_depth", the number of I/Os is "8", the module name is "lpfc820", and the number of
ports is "2".
# esxcfg-module -s "lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8" lpfc820
Input the number of I/Os ("8" in this example) for each driver parameter setting.
5 Check the setting values.
# esxcfg-module -g lpfc820
lpfc820 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8'
6 Reboot VMware ESX.
# reboot
Chapter 1 Setup Procedure for Emulex Converged Network Adapter Cards
1.2 Setting Up the Converged Network Adapter Cards
21
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(FCoE) for VMware
®
ESX
Copyright 2014 FUJITSU LIMITED
P3AM-4772-10ENZ0