7 Perform the BIOS settings for the Converged Network Adapter card.
Check the parameter values in the [Adapter Settings] window against those in the following table. For
details on how to set the values, refer to the BIOS Readme file and Converged Network Adapter card
user's guide.
Parameter Adapter Settings Remarks
BIOS Address Fixed for each card Settings cannot be changed.
BIOS Revision (*1)
Adapter Mac Address
Interrupt Level
Adapter Port Name
Host Adapter BIOS Enabled or Disabled
Set [Enabled] for SAN Boot.
Set [Disabled] for non SAN Boot.
Frame Size 2048 If the current parameter values are dif-
ferent, change them to the indicated
values.
Loop Reset Delay 5
Spinup Delay Disabled
Fibre Channel Tape Support Disabled
*1: The BIOS version of the Converged Network Adapter card is displayed. Check that the BIOS version
is the same as shown in "
Server Support Matrix".
8 Return to the [Configuration Settings] menu by pressing the [Esc] key.
9 Select [Advanced Adapter Settings] from the [Configuration Settings] menu and press the [Enter] key.
Check the parameter values in the [Advanced Adapter Settings] window against those in the following
table.
Parameter Setting value Remarks
Execution Throttle 65535 If the current parameter values are dif-
ferent, change them to the indicated
values.
LUNs per Target 8
Enable Target Reset Yes
Login Retry Count 8
Port Down Retry Count 30
Link Down Timeout 30
Operation Mode 0
Interrupt Delay Timer 0
Enable Interrupt NO
EV Controller Order Disabled
LR Enable Disabled
Primary FCF VLAN ID Disabled
10 Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.
If the BIOS settings were changed, save the settings using [Save xxxxxx]. When two or more Converged
Network Adapter cards are installed in the server, select the second or later Converged Network Adapter
card using the following steps, and set the BIOS of the selected card.
(1) Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter] key.
Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards
2.2 Setting Up the Converged Network Adapter Cards
26
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(FCoE) for VMware
®
ESX
Copyright 2014 FUJITSU LIMITED
P3AM-4772-10ENZ0
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 35 36

Comentarios a estos manuales

Sin comentarios